:tip:The electrical features are given in section Electrical features.
The example of the connection are given in section Example of connection
CN23 TerminalSimbolDescriptionAddress
1A VD1 Internal bridge 1A -1B
2A DIR1+ DIRECTION 1 outputPush-Pull Line Driver3.PULSE01
3A STEP1+ STEP 1 output
4A DIR2+ DIRECTION 2 output 3.PULSE02
5A STEP2+ STEP 2 output
6A 0V Stepper outputs common
1B VD1 Internal bridge 1A -1B
2B DIR1- DIRECTION 1 complementary outputComplementary outputs for use
on driver with Line-Driver inputs
3B STEP1- STEP 1 complementary output
4B DIR2- DIRECTION 2 complementary output
5B STEP2- STEP 2 complementary output
6B 0V Stepper outputs common
CN24 TerminalSimbolDescriptionAddress
1A VD2 Internal bridge 1A -1B
2A DIR3+ DIRECTION 3 outputPush-Pull Line Driver3.PULSE03
3A STEP3+ STEP 3 output
4A DIR4+ DIRECTION 4 output 3.PULSE04
5A STEP4+ STEP 4 output
6A 0V Stepper outputs common
1B VD2 Internal bridge 1A -1B
2B DIR3- DIRECTION 3 complementary outputComplementary outputs for use
on driver with Line-Driver inputs
3B STEP3- STEP 3 complementary output
4B DIR4- DIRECTION 4 complementary output
5B STEP4- STEP 4 complementary output
6B 0V Stepper outputs common
CN25 TerminalSimbolDescriptionAddress
1A VD3 Internal bridge 1A -1B
2A DIR5+ DIRECTION 5 outputPush-Pull Line Driver3.PULSE05
3A STEP5+ STEP 5 output
4A - n.c.
5A - n.c.
6A 0V Stepper outputs common
1B VD3 Internal bridge 1A -1B
2B DIR5- DIRECTION 5 complementary outputComplementary outputs for use
on driver with Line-Driver inputs
3B STEP5- STEP 5 complementary output
4B - n.c.
5B - n.c.
6B 0V Stepper outputs common

STEP-DIRECTION voltage settings

Inserendo uno dei vari ponticelli JP1-JP9, è possibile scegliere la Tensione di funzionamento nominale delle uscite STEP e DIR. With JP1 to JP9 jumper, you can set the nominal voltage of the STEP and DIR outputs.

:todo:Deve essere inserito un solo ponticello alla volta per ogni connettore
Se viene selezionata una delle due tensioni 5V(JP3,JP6,JP9) o 12V(JP1,JP4,JP7) i morsetti 1A e 1B devono rimanere scollegati

.

Nome
jumper
Impostazione Tensione nominale
JP1 INSERITO 12V (Tensione erogata dallo strumento)
JP2 INSERITO VD1 (Tensione che deve essere fornita ai morsetti 1A o 1B)
JP3 INSERITO 5V (Tensione erogata dallo strumento)
JP4 INSERITO 12V (Tensione erogata dallo strumento)
JP5 INSERITO VD2 (Tensione che deve essere fornita ai morsetti 1A o 1B)
JP6 INSERITO 5V (Tensione erogata dallo strumento)
JP7 INSERITO 12V (Tensione erogata dallo strumento)
JP8 INSERITO VD3 (Tensione che deve essere fornita ai morsetti 1A o 1B)
JP9 INSERITO 5V (Tensione erogata dallo strumento)
JP1,JP4,JP7
JP2,JP5,JP8